You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Sensors
  3. Radar sensors
  4. Radar range sensors
  5. R2D110

radar range sensor

R2D110

R2DAAF6KG/US/IO-LINK

radar range sensor

R2D110

R2DAAF6KG/US/IO-LINK

  • Winkelauflösung ermöglicht präzise Ausgabe der Positionskoordinaten
  • Reliable measurements even in precipitation, fog, dust and dirt
  • 8 frei konfigurierbare Überwachungszonen
  • Operating modes can be set in accordance with the specific application
  • Intuitive set-up and visualisation of the measured data using the ifm Vision Assistant software

The application area of the device depends on the base frequency used and the country in which it is operated. You will find an overview in the operating instructions and here

  • ce
  • iolink
Product characteristics
Communication interface IO-Link
Housing rectangular
Dimensions [mm] 80 x 80 x 45
Digital
Electrical design PNP/NPN; (parameterisable)
Output function normally open / normally closed; (parameterisable)
Application
Radio approval for EU/RED
Note on radio approval
The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”.
Electrical data
Operating voltage [V] 10...30 DC; (to SELV/PELV ; energy-limited circuits according to IEC/UL 61010-1 3rd ed. cl. 9.4)
Current consumption [mA] < 300; (mean value: 150 mA)
Power consumption [W] 21; (maximum)
Protection class III
Reverse polarity protection yes
Max. power-on delay time [ms] 1000
Operating frequency [GHz]
60...64
Average spectral density EIRP [dBm/MHz]
-15
Average transmitter power EIRP [dBm]
15
Inputs / outputs
Total number of inputs and outputs 3
Inputs
Inputs
IN1 activation/deactivation of the radar
Outputs
Total number of outputs 2
Output signal
OUT1 switching signal; IO-Link
OUT2 switching signal
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Digital
Electrical design PNP/NPN; (parameterisable)
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 200
Detection zone
Range [m] 0.3...50; (referred to E23014)
Angle of aperture cylindrical [°]
horizontal 140
vertical 50
Note static objects are not stably detected in the range < 1 m
Measuring/setting range
Measuring range [m] 0.3...50; (see diagram:)
Sampling rate [Hz] 20
Note static objects are not stably detected in the range < 1 m
Software / programming
Parameter setting options only via IO-Link
Interfaces
Communication interface IO-Link
Transmission type COM3 (230,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Function class Designation
0x0030 BLOB transfer
0x4000 Identification and Diagnosis
0x8101 Locator
0x8102 ProductURI
SIO mode yes
Required master port type A
Min. process cycle time [ms] 3.2
IO-Link process data (cyclical)
function bit length
Alarmzonen Status 8
Position X von Objekt 1 16
Position Y von Objekt 1 16
Geschwindigkeit X von Objekt 1 16
Geschwindigkeit Y von Objekt 1 16
Leistung von Objekt 1 8
RCS von Objekt 1 8
Konfidenz von Objekt 1 8
Position X von Objekt 2 16
Position Y von Objekt 2 16
Geschwindigkeit X von Objekt 2 16
Geschwindigkeit Y von Objekt 2 16
Leistung von Objekt 2 8
RCS von Objekt 2 8
Konfidenz von Objekt 2 8
device status 4
sensor inclination 1
IO-Link functions (acyclical) application specific tag; operating hours counter; number of trigger events; internal temperature; ROI setting; Schaltverzögerungen; Sender abschaltbar
Supported DeviceIDs
Type of operation DeviceID
default 1520
Note
For further information please see the IODD PDF file under "Downloads"
Operating conditions
Ambient temperature [°C] -40...85
Storage temperature [°C] -40...85
Protection IP 65; IP 66; IP 67; IP 69K; (with mounted connectors or protective caps)
Tests / approvals
EMC
DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD
DIN EN 61000-4-3 HF radiated 10 V/m
DIN EN 61000-4-4 Burst 2 kV
DIN EN 61000-4-6 HF conducted 10 V
DIN EN 61000-6-2 immunity / industrial environments
EN 55032 emission Class A
Impact resistance
IEC 62262 IK06 (1J)
Vibration resistance
DIN EN 60068-2-6 Fc 10 g 10 frequency cycles, 1 octave/minute, in 3 axes
Shock resistance
DIN EN 60068-2-27 Ea 50 g 11 ms half-sine; 10 shocks each in every direction along the 3 coordinate axes
Continuous shock resistance
DIN EN 60068-2-29 Eb 40 g 6 ms half-sine; 4,000 shocks each in every direction along the 3 coordinate axes
Fast temperature change
DIN EN 60068-2-14 Na TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 30 s; 300 cycles
Salt spray test
DIN EN 60068-2-11 Ka 8 test cycles
Electrical protection
DIN EN 61010-2-201 electric shock / electrical supply only via SELV/PELV circuits
MTTF [years] 53
Mechanical data
Weight [g] 399.2
Housing rectangular
Mounting flush mountable
Dimensions [mm] 80 x 80 x 45
Materials housing: PA; radome: PEI; Sealing: HNBR
Displays / operating elements
Display
switching status 2x LED, yellow
operation 1x LED, green
errors 1x LED, red
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Diagrams and graphs
Detection zone
1: azimuth
2: elevation
conditions
Reflector: 4.3“ Trihedral Corner Reflector (SAJ043-S1)
RCS: 8 dBm²
distance: 5 m
operating frequency: 62 GHz
Other data
Operating mode standard Long range, high velocity
max. distance 0.3...20 m 0.3...30 m
distance resolution 100 mm 360 mm
horizontal angular resolution (azimuth ) 10 ° 10 °
distance accuracy ± 5 mm ± 15 mm
max. velocity ± 6 m/s ± 15 m/s
velocity resolution ± 0.25 m/s ± 0.38 m/s
speed accuracy ± 0.01 m/s ± 0.04 m/s
Switching frequency 20 Hz 20 Hz
distance referred to E23013
Resolution for the detection of two objects of the same size
accuracy for a strong, point-shaped target