You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Sensors
  3. Level sensors
  4. Use in hazardous areas
  5. LMT01A

Sensor for point level detection in hazardous areas

LMT01A

LMACE-A12E-QSKG-1/US/3D/3G

Sensor for point level detection in hazardous areas

LMT01A

LMACE-A12E-QSKG-1/US/3D/3G

  • For the reliable level control in tanks and containers
  • Hygienic design for the requirements of the food and beverage industry
  • Use in liquid and viscous media and bulk materials
  • Differentiation of media by parameterisation of the switching outputs
  • For applications in hazardous areas
  • User-friendly communication and parameterisation via IO-Link
  • ce
  • fda
  • ukca
  • ex
  • ehedg
  • iolink
  • ec19352004
Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Factory setting oils; oil-based media; powder
Process connection threaded connection G 1/2 sealing cone
Application
Special feature Gold-plated contacts
Media Liquids; viscous media; powder
Cannot be used for See the operating instructions, chapter "Function and features".
Medium temperature [°C] -20...85
Probe length [mm] 11
Tank pressure [bar] -1...40
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Measuring principle capacitive
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Factory setting oils; oil-based media; powder
Response times
Response time [s] < 0.5
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
default 305
Operating conditions
Ambient temperature [°C] -20...60
Storage temperature [°C] -40...85
Protection IP 67; (when used outside the hazardous area: IP 68 / IP 69)
Tests / approvals
ATEX marking II 3D Ex tc IIIC T90°C Dc X
II 3G Ex nA IIC T4 Gc X
EMC
DIN EN 61000-6-2
DIN EN 61000-6-4 open tanks
DIN EN 61000-6-3 closed tanks
Shock resistance
DIN EN 68000-2-27 50 g (11 ms)
Vibration resistance
DIN EN 68000-2-6 20 g (10...2000 Hz)
MTTF [years] 223
Mechanical data
Weight [g] 218
Materials stainless steel (316L/1.4404); PEEK; PEI; FKM
Materials (wetted parts) PEEK; surface characteristics: Ra < 0,8 / Rz 4
Process connection threaded connection G 1/2 sealing cone
Displays / operating elements
Display
switching status LED, yellow
operating status LED, green
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated