You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. PG2898

Flush pressure sensor with analogue display

PG2898

PG-,25BREA01-MFRKG/US/ /P

Flush pressure sensor with analogue display

PG2898

PG-,25BREA01-MFRKG/US/ /P

  • Analogue display, pressure switch and transmitter in one unit
  • Excellent readability also over a long distance
  • Rotatable display with LED bar graph for switch point indication
  • Hygienic, robust stainless steel housing for the requirements of the food and beverage industry
  • Flush process connection for use in CIP and SIP processes
  • acs
  • ehedg_t
  • fcm
  • ce
  • fda
  • ukca
  • tuev_s
  • cul
  • ec19352004
  • crn
Product characteristics
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range
-0.0124...0.25 bar -12.4...250 mbar -5...100.4 inH2O
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25...125; (145 max. 1h)
Min. bursting pressure
30000 mbar 12043 inH2O
Pressure rating
6000 mbar 2400 inH2O
Type of pressure relative pressure
MAWP (for applications according to CRN) [bar] 10
Electrical data
Operating voltage [V] 18...32 DC
Current consumption [mA] < 70; (24 V)
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 6
Measuring principle hydrostatic
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; (configurable)
Electrical design PNP/NPN
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 50
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible; (scalable)
Max. load [Ω] (Ub - 10 V) / 20 mA
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
-0.0124...0.25 bar -12.4...250 mbar -5...100.4 inH2O
Set point SP
-12...400 mbar -4.8...160.6 inH2O
Reset point rP
-12.4...399.6 mbar -5...160.4 inH2O
Analogue start point
-12.4...337.6 mbar -5...135.5 inH2O
Analogue end point
50...400 mbar 20.1...160.6 inH2O
In steps of
0.2 mbar 0.1 inH2O
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,2; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,05; (0...70 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,15; (0...70 °C)
Response times
Response time [ms] < 10
Damping process value dAP [s] 0.01...30
Damping for the analogue output dAA [s] 0.01...30
Step response time analogue output [ms] 25
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 67; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 0,5/1 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 20 g (10...2000 Hz)
MTTF [years] 100
Note on approval
factory certificate available as download at www.factory-certificate.ifm
Mechanical data
Weight [g] 530.8
Materials stainless steel (1.4404 / 316L); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles 100 million
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Displays / operating elements
Display
Display unit 2 x LED, green
switching status LED, yellow
switch points LED ring, red
function display alphanumeric display, red 4-digit
measured values analogue display, 0...350° rotatable, pointer not visible when unit disconnected
measured values alphanumeric display, red 4-digit
With scale yes
Extended display range (max.)
400 mbar 160.6 inH2O
Remarks
Remarks
characteristics deviation in the extended display range: 1.5 % of the span
switch point accuracy in the extended display range: 1.5 % of the span
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated