You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Sensors
  3. Pressure sensors / Vacuum sensors
  4. Compact housing with display for pneumatics
  5. PQ3809

Pressure sensor for pneumatics

PQ3809

PQ-1-1-KHR18-KFPKG/AS/

Pressure sensor for pneumatics

PQ3809

PQ-1-1-KHR18-KFPKG/AS/

  • Reliable monitoring of the system pressure in pneumatics and in compressed air systems
  • Very high overpressure and vacuum resistance
  • Clearly visible slanted LED display
  • Red/green display for clear identification of the acceptable range
  • With programmable switching output and analogue output
  • Convenient operation via buttons or parameter setting via IO-Link
  • ce
  • ukca
  • cul
  • iolink
Product characteristics
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range
-1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa
Process connection threaded connection G 1/8 internal thread internal thread:M5
Application
Special feature Gold-plated contacts
Application for industrial applications
Conditionally suitable for other media on request
Medium temperature [°C] 0...60
Min. bursting pressure
30 bar 435 psi 886 inHg 3000 kPa
Note on min. burst pressure
max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa
Pressure rating
20 bar 290 psi 591 inHg 2000 kPa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure; differential pressure; vacuum
Electrical data
Operating voltage [V] 18...32 DC; (to SELV/PELV)
Current consumption [mA] < 50
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Overvoltage protection yes; (< 40 V)
Power-on delay time [s] 0.5
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] < 100
Number of analogue outputs 1
Analogue current output [mA] 4...20
Max. load [Ω] 500
Short-circuit protection yes
Type of short-circuit protection pulsed
Measuring/setting range
Measuring range
-1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa
Set point SP
-0.98...1 bar -14.2...14.6 psi -28.8...29.4 inHg -98...100 kPa
Reset point rP
-0.99...0.99 bar -14.4...14.4 psi -29.1...29.1 inHg -99...99 kPa
In steps of
0.01 bar 0.2 psi 0.3 inHg 1 kPa
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,5
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,25
Long-term stability [% of the span] < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K] 0,2; (0...60 °C)
Temperature coefficient span [% of the span / 10 K] 0,2; (0...60 °C)
Response times
Response time [ms] < 6
Delay time programmable dS, dr [s] 0; 0,002...5
Step response time analogue output [ms] 6
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 FDIS
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
default 366
Operating conditions
Ambient temperature [°C] 0...70
Storage temperature [°C] -25...85
Protection IP 65
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 437
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 87
Materials PBT; FKM; polyester
Materials (wetted parts) brass; FKM; silicon (coated); PBT
Min. pressure cycles 50 million
Process connection threaded connection G 1/8 internal thread internal thread:M5
Displays / operating elements
Display
Display unit 4 x LED, green
switching status 1 x LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit bar; kPa; psi; inHg
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M8; coding: A; Contacts: gold-plated