You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Sensors
  3. Temperature sensors
  4. Self-monitoring transmitters for the food and beverage industry
  5. TCC261

Temperature transmitter

TCC261

TCC250K1ED06-A-DKG/US

Temperature transmitter

TCC261

TCC250K1ED06-A-DKG/US

  • Immediate notification of deviations in accuracy
  • Improved quality assurance in between calibration intervals
  • Robust design for permanently precise measurements even in demanding environments
  • Transparent sensor monitoring thanks to logging of the diagnostic values
  • Simulation function simplifies installation
  • Precise analogue output and user-friendly communication via IO-Link
  • ce
  • fda
  • ukca
  • iolink
  • cul
  • ec19352004
  • crn
Product characteristics
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range
-25...160 °C -13...320 °F
Communication interface IO-Link
Process connection diameter Ø 6 mm
Installation length EL [mm] 250
Application
Special feature Gold-plated contacts
Measuring element 1 x Pt 1000
Reference element 1 x NTC
Media liquids and gases
Pressure rating [bar] 160
Electrical data
Operating voltage [V] 18...32 DC; ("supply class 2" to cULus)
Current consumption [mA] 10; (24 V)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 6
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal analogue signal; IO-Link; calibration check status
Electrical design PNP/NPN
Number of digital outputs 1
Output function normally closed; (diagnostic signal)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 100
Diagnostic output calibration check status and error diagnostics
Number of analogue outputs 1
Analogue current output [mA] 4...20
Max. load [Ω] (Ub - 15 V) x 50
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
-25...160 °C -13...320 °F
Note on measuring range
scalable
Factory setting -10...150 °C / 14...302 °F
Calibration check limit [K] 0.5...3
In steps of [K] 0.05
Resolution
Resolution of analogue output [K] 0.05
Accuracy / deviations
Precision analogue output [K] ± 0,2
Precision IO-Link [K] ± 0,2
Temperature coefficient analogue output [% of the span / 10 K] < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C)
Temperature coefficient IO-Link [% of the span / 10 K] < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C)
Response times
Dynamic response T05 / T09 [s] 1,5 / 4
Software / programming
Parameter setting options Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Digital Measuring Sensor, Common Profile, Blob Transfer
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 1
Min. process cycle time [ms] 4.4
IO-Link resolution temperature [K] 0.01
Supported DeviceIDs
Type of operation DeviceID
default 1129
Operating conditions
Ambient temperature [°C] -25...70
Note on ambient temperature
max. internal device temperature: 125 °C
Storage temperature [°C] -40...100
Protection IP 68; IP 69K
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 68000-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 35 g (10...2000 Hz)
MTTF [years] 329
Note on approval
factory certificate available as download at www.factory-certificate.ifm
UL approval
UL Approval no. K021
File number UL E217884
Mechanical data
Weight [g] 271.9
Dimensions [mm] Ø 50 / L = 293.5
Materials stainless steel (1.4404 / 316L); PEI; FKM; PFA
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK
Process connection diameter Ø 6 mm
Surface characteristics Ra/Rz of the wetted parts Ra: < 0.8
Probe diameter [mm] 6
Installation length EL [mm] 250
Remarks
Remarks
MS = set measuring span
operating voltage "supply class 2" according to cULus
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated