Measuring range |
|
||
---|---|---|---|
Installation length EL [mm] | 42 |
Special feature | Gold-plated contacts | |
---|---|---|
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class B) | |
Media | liquids and gases | |
Pressure rating [bar] | 160 | |
Note on pressure rating |
|
|
Minimum installation depth [mm] | 15 |
Protection class | III |
---|
Probe length L [mm] | 42 | ||
---|---|---|---|
Measuring range |
|
Accuracy [K] | ± (0,30 K + 0,005 x|t|) |
---|
Dynamic response T05 / T09 [s] | 6 / 25; (to DIN EN 60751) |
---|
Ambient temperature [°C] | -25...80 | |
---|---|---|
Note on ambient temperature |
|
|
Protection | IP 67 |
Weight [g] | 113.2 |
---|---|
Dimensions [mm] | Ø 10 |
Materials | stainless steel; FKM |
Materials (wetted parts) | stainless steel (316L/1.4404) |
Probe diameter [mm] | 10 |
Installation length EL [mm] | 42 |
Remarks |
|
|
---|---|---|
Pack quantity | 1 pcs. |
Connection | Cable: 2 m, FKM |
---|---|
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |