Non-contact fail-safe inductive sensor. |
|
| |
|
 |
|
| |
|

|
|
Direct detection of metal solves new applications.
- Suitable for operator and machine safety.
- Reliable function without specific coded target.
- Connection of the sensors to safety PLCs, bus systems and relays possible.
- Meets the requirements of IEC 61508 SIL3 and ISO 13849-1 PL e.
- Certified to IEC 62061, SILcl3.
Self-monitoring design without coded magnet or coded target.
2 x PNP switching outputs (normally closed function) Because of the window technology used, i.e. an enable zone monitored for target position and dwell time, a counterpart, e.g. a magnet or a special mechanical target is not required. If the target is removed from the enable zone, the output circuits open. The fail-safe sensor can be connected to approved two-channel evaluation units without crossmonitoring that are suitable for positive-switching noncontact guards. In case of a fault, e.g. cross fault of the wires, the sensor passes into the defined safe state.
GI701S - M12 connector / Output function 2 PNP no (OSSD)
Further information: Bulletin (PDF file 304 kB).
|
|
|
|